Dear All,
I just installed netweaver 7.3, after which I'm able to access http://<host ip>:50100/startpage ; I'm not able to access any options inside this page .. like NWA orr Systeminfo etc ..
At the start it said : 403 Access forbidden .. I wasn't able to access the pages either from the LOCAL HOST ( where the NW7.3 is installed )
or remotely .. it was the same 403 Access forbidden error !!
Then I had the ICM_filter_rules.txt edited as mentioned in Note 1451753 ..
Now I'm able to aceess the portal and the NWA , Systeminfo etc from REMOTE MACHINES / REMOTE DESKTOPS .. Works fine !!
But when I'm logged into the Server ( Local Host where NW 7.3 is installed ) I'm unable to access the NWA, System info etc .. still ..
The only change is that .. the error has changed from 403 forbidden to ..
500 - Internal server error ...
I found my problem very similar to one of the thread discussions on SCN back in 2011 .. Where they have resolved it ..
The steps they followed ..
the problem was the SPNEGO Template = 0
To resolve the issue, open offlinecfgeditor
in edit mode, go to security/configurations/ticket
highlight the "template=spnego" key and delete it
I'm also loggged into the configtool in edit mode, I have navigated to SECURITY/CONFIGURATIONS/TICKET
but can't find the "template=spnego" they are talking about in the thread ;(
I've cross checked up and down .. can't find a key by that description !!
Can someone help with the exact and precise steps so that these tools can be accessed from the LOCAL SERVER too ..
Thanks in advance
Krish