Hi,
I've got a new Ricoh Aficio MP 6001. We would liket to change input try and output try from our ABAP system.
So we have copy RC001U18 to new several custom device type and we would change input try and output try for each one.
But... it seams that print control are ignored, from Ricoh documentation:
TRO__ === Output bins === (*3)
TRO01 (DEVICE-SPECIFIC) <esc>&l1G
TRO02 (DEVICE-SPECIFIC) <esc>&l100G
TRO03 (DEVICE-SPECIFIC) <esc>&l101G
TRO04 (DEVICE-SPECIFIC) <esc>&l2G
TRO05 (NOT SUPPORTED) <esc>&l102G
TRO06 (NOT USED) <empty>
TRO07 (NOT USED) <empty>
TRO08 (NOT USED) <empty>
TRO09 (NOT USED) <empty>
TRO10 (DEVICE-SPECIFIC) <esc>&l3G
TRO11 (DEVICE-SPECIFIC) <esc>&l4G
TRO12 (DEVICE-SPECIFIC) <esc>&l5G
TRO13 (DEVICE-SPECIFIC) <esc>&l6G
TRO14 (DEVICE-SPECIFIC) <esc>&l7G
TRO15 (DEVICE-SPECIFIC) <esc>&l8G
TRO16 (DEVICE-SPECIFIC) <esc>&l9G
TRO17 (DEVICE-SPECIFIC) <esc>&l10G
TRO18 (DEVICE-SPECIFIC) <esc>&l11G
TRO19 (DEVICE-SPECIFIC) <esc>&l12G
TROST (DEVICE-SPECIFIC) <esc>&l1G
TRY__ === Input bins === (*3,*4)
TRY01 (DEVICE-SPECIFIC) <esc>&l8H
TRY02 (DEVICE-SPECIFIC) <esc>&l1H
TRY03 (DEVICE-SPECIFIC) <esc>&l4H
TRY04 (DEVICE-SPECIFIC) <esc>&l30H
TRY05 (DEVICE-SPECIFIC) <esc>&l5H
TRY06 (NOT USED) <empty>
TRY07 (NOT USED) <empty>
TRY08 (NOT USED) <empty>
TRY09 (NOT USED) <empty>
TRYB4 (DEVICE-SPECIFIC) <esc>&l22H
TRYB5 (DEVICE-SPECIFIC) <esc>&l23H
TRYB6 (DEVICE-SPECIFIC) <esc>&l24H
TRYB7 (DEVICE-SPECIFIC) <esc>&l25H
TRYEN Envelope Feeder <esc>&l6H
TRYME Manual Envelope Feeder <esc>&l3H
TRYMN Bypass / Manual Tray <esc>&l2H
TRYST (DEVICE-SPECIFIC) <esc>&l0H
I've try with:
...
##======================================================================
## [PJL.16] OUTPUT BIN 1/2
@PJL SET OUTBIN = UPPER \r\n
##======================================================================
...
## [PCL.01] INPUT BIN
###\p<POSSOPT:01>
\e&l3H
##======================================================================
## [PCL.02] OUTPUT BIN 2/2
###\p<POSSOPT:02>
\e&l101G
...
but no success, each spool are printed on default input/output try