Dear ecperts,
I am having error when try to start saprouter service
Environment variables have been set:
Below is dev_rout log:
---------------------------------------------------
trc file: "dev_rout", trc level: 1, release: "742"
---------------------------------------------------
Tue Dec 29 01:44:27 2015
SAP Network Interface Router, Version 40.4
command line arg 0: saprouter
command line arg 1: -r
command line arg 2: -S
command line arg 3: 3299
command line arg 4: -K
command line arg 5: p:CN=gitvm063, OU=0000524233, OU=SAProuter, O=SAP, C=DE
SncInit(): Initializing Secure Network Communication (SNC)
PC with Windows NT (mt,ascii,SAP_UC/size_t/void* = 8/64/64)
GetUserName()="sm3adm" NetWkstaUser="sm3adm"
SncInit(): Trying builtin default as a
gssapi library name: "sncgss64.dll".
*** ERROR => DlLoadLib()==DLENOACCESS - LoadLibrary("sncgss64.dll")
Error 126 = "The specified module could not be found." [dlnt.c 294]
*** ERROR => SncPDLInit()==SNCERR_INIT, Adapter #1 (sncgss64.dll) not loaded [D:/depot/b 732]
<<- SncInit()==SNCERR_INIT
sec_avail = "false"
*** ERROR => NiSncInit: SncInit failed (sncrc=-1) [nisnc.c 555]
*** ERROR => main: NiSncInit failed (rc=-17) [nirout.cpp 1958]
*****************************************************************************
*
* ERROR SNC processing failed:
* SncInit
*
* TIME Tue Dec 29 01:44:27 2015
* RELEASE 742
* COMPONENT NI (network interface)
* VERSION 40
* RC -17
* MODULE D:/depot/bas/742_REL/src/base/ni/nisnc.c
* LINE 553
* DETAIL NiSncInit: sncrc=-1
Tue Dec 29 01:44:27 2015
* COUNTER 4
*
*****************************************************************************
<<- ERROR: SncDone()==SNCERR_INIT_FIRST
I have uploaded my steps of configuration in below URL. Please have a look
SAPRouter Installation.xlsx - Google Drive
Thank you.
BR,
Fadzly Iqbal